Monitoring the current value
Current feed value and Machine feed value are stored in the following buffer memory areas, and can be read using a DFROM
(P) instruction or DMOV (P) instruction from the CPU module.
[Md.20] Current feed value
[Md.21] Machine feed value
■Program example
The following shows an example of the program that stores the current feed value of the axis 1 in the specified device.
Classification
Label Name
Module label
FX5PG_1.stnAxisMonitorData_Axis_D[0].dCurrentFeedValue_D
Global label, local
Define the global label or local label as follows. Setting Assign (Device/Label) for labels is not necessary because the unused internal
label
relay and data device are automatically assigned to the labels.
9 MAJOR POSITIONING CONTROL
104
9.1 Overview of the Major Positioning Controls
Buffer memory address
Axis 1
800, 801
802, 803
Axis 2
900, 901
902, 903
Description
Axis 1: Current feed value