■Positioning data to be set
To use the 2-axis circular interpolation control with sub point specified (INC circular sub), set the following positioning data.
: Always set
: Set as required
: Setting not required
Setting item
[Da.1]
Operation pattern
[Da.2]
Control method
[Da.3]
Acceleration time No.
[Da.4]
Deceleration time No.
[Da.5]
Axis to be interpolated
[Da.6]
Positioning address/movement amount
[Da.7]
Arc address
[Da.8]
Command speed
[Da.9]
Dwell time
[Da.10]
M code
[Da.27]
M code ON signal output timing
[Da.28]
ABS direction in degrees
[Da.29]
Interpolation speed specification method
For details on the settings, refer to the following.
Page 410 Positioning Data
Set a value in [Da.8] Command speed so that the speed of each axis does not exceed the value in [Pr.8]
Speed limit value. (The speed limit does not function for the speed calculated using the positioning module.)