[Cd.183] Execution prohibition flag
• If the Execution prohibition flag is on when the Positioning start signal turns on, positioning control does not start until this
flag turns off. (no pulse output)
• The Execution prohibition flag is acquired when positioning starts.
Execution prohibition flag
During execution prohibition
Not during execution prohibition
For details on the pre-reading start function, refer to the following.
Page 257 Pre-reading start function
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Cd.183] Execution prohibition flag
■Default value
The default value is 0 for all the axes.
[Cd.184] Positioning start signal
The OPR operation or positioning operation is started.
• Positioning start signal is valid at the rising edge, and the operation is started.
• The Start during operation warning (warning code: H0900) occurs when the positioning start signal turns on during the
BUSY state.
• The positioning start signal is acquired immediately.
Buffer memory configuration
b15 b14 b13 b12 b11 b10 b9
Positioning start request ([Cd.184] Positioning start signal: b0)
• 0: No positioning start request
• 1: Positioning start request
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Cd.184] Positioning start signal
■Default value
The default value is 0: No positioning start request for all axes.
Axis 1
30103
b8
b7
b6
b5
b4
b3
b2
(1)
Axis 1
30104
Setting value
1
Other than 1
Stored contents
(1)
Use prohibited
b1
b0
(2)
Positioning start request
(2)
17 DATA USED FOR POSITIONING CONTROL
Axis 2
30113
Stored value
Fixed to 0
0, 1
Axis 2
30114
17.8 Control Data
17
471