Interrupt setting

Set the interrupt function of the positioning module.
Item
Interrupt factor setting
Axis No. for interrupt factor
Interrupt pointer
*1 For details on the available interrupt pointers, refer to the following.
MELSEC iQ-F FX5 User's Manual (Application)
Setting range
• 0: Do not detect (Default value)
• 1: Status_M code ON
• 2: Status_Error detection
• 3: BUSY
• 4: Status_Start complete
• 5: Status_Positioning complete
• 100: External I/O signal_Lower limit signal
• 101: External I/O signal_Upper limit signal
• 102: External I/O signal_Drive unit READY signal
• 103: External I/O signal_Stop signal
• 104: External I/O signal_Special start instruction
• 105: External I/O signal_Zero signal
• 106: External I/O signal_Near-point dog signal
• 107: External I/O signal_Deviation counter clear signal
• 200: Status_In speed control flag
• 201: Status_Speed-position switching latch flag
• 202: Status_Command in-position flag
• 203: Status_OPR request flag
• 204: Status_OPR complete flag
• 205: Status_Position-speed switching latch flag
• 206: Status_Warning detection
• 207: Status_Speed change 0 flag
• 300: Deceleration start flag
• 301: Analysis complete flag
• 0: All axes (default value)
• 1: Axis 1
• 2: Axis 2
*1
I50 to I177
Reference
Page 473 [Pr.900] Interrupt factor setting
Page 473 [Pr.901] Axis No. for interrupt factor
14 PARAMETER SETTING