Continuous Operation Interrupt Function - Mitsubishi Electric MELSEC iQ-F Series FX5 User Manual

Positioning control - intelligent function module
Hide thumbs Also See for MELSEC iQ-F Series FX5:
Table of Contents

Advertisement

Continuous operation interrupt function

Continuous operation interrupt function can interrupt the positioning operations in the continuous positioning control and
continuous path control. When the continuous operation is interrupted, the control will stop when the operation of the
positioning data being executed is completed. To interrupt the continuous operation, set 1: Continuous operation interrupt
request for [Cd.18] Continuous operation interrupt request.
In the continuous path control, the deceleration stop is performed according to the deceleration time set in [Da.4] Deceleration
time No.
Operation when the continuous operation is interrupted
V
Stop command turns on or
continuous operation interrupt
request is received
Starts
Positioning data No.10
Restrictions
• When Continuous operation interrupt request is executed, the positioning will end. Thus, the operation cannot be restarted
after the stop. If [Cd.6] Restart command is issued, Restart not possible (Warning code: 0902H) will occur.
• Even if a stop command is turned on after Continuous operation interrupt request is executed, the continuous operation
interrupt request cannot be canceled. Thus, if the restart is executed after the stop is executed by turning on the stop
command, the operation will stop when the positioning data No. where Continuous operation interrupt request was
executed is completed.
Axis 1
Continuous operation interrupt request
Positioning via positioning data No.10
Stop processing after the stop command turns on
Positioning data No.11
Positioning via
positioning data No.11
Stop processing after reception of the
continuous operation interrupt request
Positioning data No.12
Positioning via positioning data
No.12 is not executed
End of positioning via the continuous
operation interrupt function
Axis 2
t
12 CONTROL SUB FUNCTION
12.8 Function Related to Stop
12
269

Advertisement

Table of Contents
loading

Table of Contents