Mitsubishi Electric MELSEC iQ-F Series FX5 User Manual page 356

Positioning control - intelligent function module
Hide thumbs Also See for MELSEC iQ-F Series FX5:
Table of Contents

Advertisement

■Detailed parameter 2
Buffer memory address
Decimal (Hexadecimal)
Axis 1
36
(24H)
37
(25H)
38
(26H)
39
(27H)
40
(28H)
41
(29H)
42
(2AH)
43
(2BH)
44
(2CH)
45
(2DH)
46
(2EH)
47
(2FH)
48
(30H)
49
(31H)
50
(32H)
51
(33H)
52
(34H)
53
(35H)
54
(36H)
55
(37H)
56
(38H)
57
(39H)
58
(3AH)
59
(3BH)
60
(3CH)
61
(3DH)
62
(3EH)
17 DATA USED FOR POSITIONING CONTROL
354
17.2 List of Buffer Memory Addresses
Name
Axis 2
186
[Pr.25] Acceleration time 1
(BAH)
187
(BBH)
188
[Pr.26] Acceleration time 2
(BCH)
189
(BDH)
190
[Pr.27] Acceleration time 3
(BEH)
191
(BFH)
192
[Pr.28] Deceleration time 1
(C0H)
193
(C1H)
194
[Pr.29] Deceleration time 2
(C2H)
195
(C3H)
196
[Pr.30] Deceleration time 3
(C4H)
197
(C5H)
198
[Pr.31] JOG speed limit value
(C6H)
199
(C7H)
200
[Pr.32] JOG operation acceleration time selection
(C8H)
201
[Pr.33] JOG operation deceleration time selection
(C9H)
202
[Pr.34] Acceleration/deceleration processing selection
(CAH)
203
[Pr.35] S-curve ratio
(CBH)
204
[Pr.36] Sudden stop deceleration time
(CCH)
205
(CDH)
206
[Pr.37] Stop group 1 sudden stop selection
(CEH)
207
[Pr.38] Stop group 2 sudden stop selection
(CFH)
208
[Pr.39] Stop group 3 sudden stop selection
(D0H)
209
[Pr.40] Positioning complete signal output time
(D1H)
210
[Pr.41] Allowable circular interpolation error width
(D2H)
211
(D3H)
212
[Pr.42] External command function selection
(D4H)
Default
Auto refresh
value
1000
1000
1000
1000
1000
1000
20000
0
0
0
100
1000
0
0
0
300
100
0

Advertisement

Table of Contents
loading

Table of Contents