[Pr.40] Positioning complete signal output time
Set the output time of Positioning complete signal ([Md.31] Status: b15) output from the positioning module in units of ms.
A positioning completes when the set dwell time is elapsed after the positioning module terminates outputting pulses.
For the interpolation control, Positioning completed signal of interpolation axis is output only for the time set to the reference
axis.
PLC
CPU
module
Positioning start signal
([Cd.184])
Positioning complete signal
([Md.31] Status: b15)
Positioning start signal
Start complete signal
BUSY signal
Positioning complete signal
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Pr.40] Positioning complete signal output time
■Setting range
The setting range is 0 to 65535.
■Default value
The default value is 300 for all the axes.
Positioning
module
M
Axis 1
59
Positioning
Positioning complete signal
(after the dwell time)
Output time
Axis 2
209