Relation between the software stroke limit function and various controls
: Check valid
: Check is not performed when the current feed value is not updated at the setting of Current feed value in "[Pr.14] Software stroke limit" selection during the
speed control. (Page 388 [Pr.21] Current feed value during speed control)
: Check is not performed (check invalid)
: Valid only when "0: Valid" is set in [Pr.15] Software stroke limit valid/invalid setting.
Control type
OPR control
Machine OPR control
Fast OPR control
Major positioning
Position control
control
1/2-axis speed control
Speed-position switching control, Position-
speed switching control
Other controls
Manual control
JOG operation, Inching operation
Manual pulse generator operation
*1 The value in [Md.20] Current feed value differs depending on the setting of [Pr.21] Current feed value during speed control.
*2 When the unit is degree, the limit check is not performed during the speed control.
*3 When the unit is degree, the limit check is not performed.
Limit check
1-axis linear control
2-axis linear
interpolation control
1-axis fixed-feed
control
2-axis fixed-feed
control
2-axis circular
interpolation control
*1*2
*1*2
Current value change
JUMP instruction,
NOP instruction ,
LOOP to LEND
*3
*3
Processing at check
Check is not performed.
(1) and (2) in the following section are checked.
Page 234 Details of the software stroke limit check
■For speed control
The machine decelerates and stops when the software
stroke limit range is exceeded.
■For position control
The operation is not performed if the target address is
outside the software stroke limit range.
The current value change is not performed if the new current
value is outside the software stroke limit range.
Check is not performed.
(1) and (2) in the following section are checked.
Page 234 Details of the software stroke limit check
The machine decelerates and stops when the software
stroke limit range is exceeded. The operation can be started
only toward the direction of the movable range if the target
address is outside the software stroke limit range.
12 CONTROL SUB FUNCTION
12.4 Function to Limit Control