M code ON signal OFF request
When M code ON signal ([Md.31] Status: b12) turns on, the signal must be turned off by a program. To turn off M code ON
signal, set 1 (M code ON signal is turned OFF) in [Cd.7] M code ON signal OFF request.
Setting item
[Cd.7]
M code ON signal OFF
request
For details on the settings, refer to the following.
Page 458 [Cd.7] M code ON signal OFF request
If M code ON signal is not turned off, the following processing will be performed. (The processing depends on the setting of
[Da.1] Operation pattern.)
[Da.1] Operation pattern
00
Independent positioning control
(positioning complete)
01
Continuous positioning control
11
Continuous path control
[Cd.184] Positioning
OFF
start signal
[Md.141] BUSY signal
OFF
M code ON signal
OFF
([Md.31] Status: b12)
[Cd.7] M code ON signal
OFF request
[Md.25] Valid M code
V
Positioning
[Da.1] Operation pattern
*1 m1 through m3 represent the configured M codes.
If the M code output function is not required, set 0 in [Da.10] M code, one of the setting items of positioning
data.
Setting
Setting detail
value
1
Set 1: M code ON signal is turned OFF.
Processing
The next positioning data No. will not be executed until M code ON signal is turned off.
The next positioning data No. is performed. If an M code is set to the next positioning data, M code
ON signal ON (Warning code: 0992H) will occur.
ON
ON
ON
0
1
0
1 0
m2
m1
m3
*1
*1
*1
11
11
A warning is triggered at this timing.
t
00
Buffer memory address
Axis 1
Axis 2
1504
1604