Repeated start (FOR condition)

In Repeated start (FOR condition), the data between the block start data in which 5: FOR condition is set in [Da.13] Special
start instruction and the block start data in which 6: NEXT start is set in [Da.13] Special start instruction is repeatedly
implemented until the conditions set in the condition data are established.
The condition judgment is implemented when switching to the point of 6: NEXT start (Before the positioning at the NEXT start
point) is implemented. (Specify the condition data in [Da.14] Parameter of the block start data in which 5: FOR condition is set
in [Da.13] Special start instruction.)
The following shows setting examples and a control example in which Block start data and Positioning data are set as shown
in the setting examples.
Setting example
■Block start data settings
Axis 1 block start data
1st point
2nd point
3rd point
Condition data No. has been set in [Da.14] Parameter.
■Positioning data settings
Axis 1 positioning data
No.
1
2
3
10
11
50
51
Control example
The following describes the control to be executed when the operation using the 1st point block start data of the axis 1 is
started.
Condition judgment target
(1)
(2)
The condition judgment set in the condition data No.5 of the
axis 1 is performed.
*1 Conditions are judged when switching to the NEXT start point (3rd point in the settings example) (before positioning of the NEXT start
point is implemented).
10 ADVANCED POSITIONING CONTROL
176
10.3 Setting the Block Start Data
[Da.11] Shape
1: Continue
1: Continue
0: END
[Da.1] Operation pattern
01: Continuous positioning control
01: Continuous positioning control
00: Positioning complete
11: Continuous path control
00: Positioning complete
01: Continuous positioning control
00: Positioning complete
*1
[Da.12] Start data No.
[Da.13] Special start
instruction
1
5: FOR condition
10
0: Start block
50
6: NEXT start
Compatible block start data
1st point
2nd point
3rd point
Control details
The positioning data No.1, 2, 3, 10, and 11 of the axis 1 are executed.
• Conditions not established: Implement "Positioning data No. 50 and 51", and go to
(1).
• Conditions established:Implement "Positioning data No. 50 and 51", and stop
positioning.
[Da.14] Parameter
5
Positioning data No. 1 to 3 are started en
block
Positioning data No. 10 and 11 are started en
block
Start positioning data No. 50 and 51 en block
(If the conditions are not established, repeat
start from 1st to 3rd point)