Positioning control - intelligent function module
Hide thumbs Also See for MELSEC iQ-F Series FX5:
Table of Contents

Advertisement

• If the time set in [Pr.49] OPR dwell time elapses before stopping at the stopper, the workpiece will stop at that position, and
the position will be set as an OP. In this case, no error will occur.
Machine OPR start
([Cd.184] Positioning start signal)
OPR request flag
([Md.31] Status: b3)
OPR complete flag
([Md.31] Status: b4)
Deviation counter clear output
[Md.26] Axis operation status
[Md.34] Movement amount
after near-point dog ON
[Md.20] Current feed value
[Md.21] Machine feed value
[Md.35] Torque limit stored value
• The near-point dog must be on until the workpiece hits the stopper. If there is a section in which the near-point dog is off
between the near point dog and the stopper, and a machine OPR operation is executed from a point in the section, the
workpiece will hit the stopper at the OPR speed.
• If the machine OPR is started while the near-point dog is on, the workpiece starts traveling at the speed set in [Pr.47] Creep
speed.
• When the machine OPR has been stopped by a stop signal, perform the machine OPR again. If the restart command is
turned ON after the stop by a stop signal, OPR restart not possible (Error code: 1946H) occurs.
8 OPR CONTROL
80
8.2 Machine OPR
V
[Pr.46] OPR speed
Torque limit
Near-point dog
OFF
ON
OFF
ON
OFF
OFF
Standby
OPR
0
Not set
Store traveled value
Not set
Torque limit setting value
Not set
[Pr.47] Creep speed
Torque limit enabled range
ON
Dwell time measurement
ON
[Pr.55] Deviation counter clear signal output time
Standby
OP address
OPR torque limit value
Stopper
t
Dwell time UP