Mitsubishi Electric MELSEC iQ-F Series FX5 User Manual page 387

Positioning control - intelligent function module
Hide thumbs Also See for MELSEC iQ-F Series FX5:
Table of Contents

Advertisement

[Pr.14] Software stroke limit selection
Set whether to apply the software stroke limit to Current feed value or Machine feed value. The software stroke limit is
validated according to the set value.
Software stroke limit selection
Apply the software stroke limit to the current feed value
Apply the software stroke limit to the machine feed value
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Pr.14] Software stroke limit selection
■Default value
The default value is 0: Apply the software stroke limit to the current feed value for all the axes.
[Pr.15] Software stroke limit valid/invalid setting
Set whether to validate the software stroke limit during the JOG operation, inching operation, and manual pulse generator
operation.
Software stroke limit valid/invalid setting
Software stroke limit is valid during the JOG operation, inching operation, and manual pulse generator operation
Software stroke limit is invalid during the JOG operation, inching operation, and manual pulse generator operation
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Pr.15] Software stroke limit valid/invalid setting
■Default value
The default value is 0: Software stroke limit is valid during the JOG operation, inching operation, and manual pulse generator
operation for all the axes.
[Pr.16] Command in-position width
Set the remaining distance that turns on the command in-position. The command in-position signal is used as a front-loading
signal of the positioning complete signal. When positioning control starts, Command in-position flag (bit 2) in [Md.31] Status
turns off, and Command in-position flag turns on at the set position of the command in-position signal.
Speed
Start of position control
Command in-position flag
Setting value
0
1
Axis 1
22
Axis 1
23
[Pr.16] Command in-position width
ON
OFF
17 DATA USED FOR POSITIONING CONTROL
Axis 2
172
Setting value
0
1
Axis 2
173
17.3 Basic Setting
17
385

Advertisement

Table of Contents
loading

Table of Contents