[Da.19] Parameter 2
Set the parameters according to the value set in [Da.16] Condition operator.
Setting of [Da.16] Condition
operator
01H: **=P1
02H: **≠P1
03H: **≤P1
04H: **≥P1
05H: P1≤**≤P2
06H: **≤P1, P2≤**
07H: DEV=ON
08H: DEV=OFF
10H: Axis 1 specification
20H: Axis 2 specification
■Buffer memory address
For the buffer memory address of this area, refer to the following.
Page 544 Condition data
■Default value
The default value is 0 for all the axes.
17 DATA USED FOR POSITIONING CONTROL
428
17.6 Condition Data
Setting
Description
value
Not used. (Setting this item is not required.)
Numerical
Set the value of P2 to be equal to or greater than the value of P1 (P1 ≤ P2).
value
If P1 is greater than P2 (P1 > P2), Condition data error (Error code: 1A04H) occurs.
(bit number)
Not used. (Setting this item is not required.)