Operation timing and the processing time
The following shows the details on the operation timing and processing time in the fast OPR.
[Cd.184] Positioning start signal
[Md.141] BUSY signal
Start complete signal
([Md.31] Status: b14)
[Md.26] Axis operation status
External pulse output
(PULSE)
Positioning operation
Normal timing time
t1
0.2 to 0.3 ms
Precautions during the operation
• The fast OPR can only be implemented after the OP is established by implementing the machine OPR. Otherwise, OPR
request ON (Error code: 1945H) occurs. (OPR request flag ([Md.31] Status: b3) must be OFF.)
• If the pulse for the fraction after the decimal point is cleared to 0 by using the current value change or fixed-feed control,
executing the fast OPR causes an error equivalent to the cleared pulse.
• When a limitless-feed operation is executed by the speed control and the machine feed value overflows or underflows
once, the fast OPR cannot be executed normally.
• OPR complete flag ([Md.31] Status: b4) does not turn ON.
• The axis operation status during the fast OPR is Position control.
8 OPR CONTROL
92
8.3 Fast OPR
t1
Standby
Position control
t2
t2
0.1 ms or less
t3
Standby
t3
0 to 0.88 ms