[Pr.3] Movement amount per rotation (32 bits) (Al)
Set the distance of machine movement (movement amount) per rotation of the motor shaft with 32 bits. When [Pr.62]
Electronic gear selection is set to 1: 32 bits, this area is valid. When the movement amount per rotation of the motor shaft
exceeds the setting range of [Pr.3] Movement amount per rotation (16 bits) in the system used, use this area.
When the movement amount per rotation is set with this area, the adjustment with [Pr.4] Unit magnification is unavailable.
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Pr.3] Movement amount per rotation (32 bits) (Al)
■Setting range
The setting range depends on the setting of [Pr.1] Unit setting.
Setting of [Pr.1] Unit setting
0: mm
1: inch
2: degree
3: pulse
*1 When this buffer memory area is set with programs, a calculation is performed in the positioning module to convert a setting value to the
value in each unit. For setting this buffer memory area, take the value after the unit conversion into consideration.
■Default value
The default value is 20000 for all the axes.
17 DATA USED FOR POSITIONING CONTROL
380
17.3 Basic Setting
Axis 1
104
105
Setting value via GX Works3
0.1 to 20000000.0 (μm)
0.00001 to 2000.00000 (inch)
0.00001 to 2000.00000 (degree)
1 to 200000000 (pulse)
Axis 2
254
255
Setting value with programs
-1
μm)
1 to 200000000 (×10
-5
1 to 200000000 (×10
inch)
-5
1 to 200000000 (×10
degree)
1 to 200000000 (pulse)
*1