Hitachi WJ200-001S Instruction Manual page 610

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Register
Function name
No.
1345h to
(Reserved)
1348h
Operation level at O
1349h
disconnection
Operation level at OI
134Ah
disconnection
134Bh to
(reserved)
134Dh
134Eh
Ambient temperature
134Fh to
(reserved)
1350
Cumulative input power data
1351h
clearance
1352h
Watt-hour display gain
1353h to
(Reserved)
1354h
*1
1355h
Start frequency
1356h
Carrier frequency
Initialization mode (parameters
1357h
or trip history)
1358h
Country code for initialization
Frequency scaling conversion
1359h
factor
135Ah
STOP key enable
135Bh
Restart mode after FRS
Automatic
carrier
135Ch
reduction
135Dh
Dynamic braking usage ratio
135Eh
Stop mode selection
135Fh
Cooling fan control
1360h
Clear elapsed time of cooling fan
Initialization target data
1361h
1362h
Dynamic braking control
1363h
Dynamic braking activation level
1364h
BRD resistor value
1365h to
(Reserved)
1366h
1367h
Free-setting V/f frequency (1)
1368h
Free-setting V/f voltage (1)
1369h
Free-setting V/f frequency (2)
136Ah
Free-setting V/f voltage (2)
136Bh
Free-setting V/f frequency (3)
136Ch
Free-setting V/f voltage (3)
136Dh
Free-setting V/f frequency (4)
136Eh
Free-setting V/f voltage (4)
136Fh
Free-setting V/f frequency (5)
1370h
Free-setting V/f voltage (5)
1371h
Free-setting V/f frequency (6)
1372h
Free-setting V/f voltage (6)
1373h
Free-setting V/f frequency (7)
1374h
Free-setting V/f voltage (7)
: Range modified from version 3.0
*1
Function
R/W
code
-
-
b070
R/W
b071
R/W
-
-
R/W -10 to 50
b075
-
-
b078
R/W Clearance by setting "1"
b079
R/W 1 to 1000
-
-
b082
R/W 1 to 999
b083
R/W 20 to 150
b084
R/W
b085
R/W 0 (area A), 1 (area B)
b086
R/W 1 to 9999
b087
R/W 0 (enabling), 1 (disabling), 2 (disabling only stop)
b088
R/W
frequency
b089
R/W
b090
R/W 0 to 1000
b091
R/W 0 (deceleration until stop), 1 (free-run stop)
b092
R/W
b093
R/W 0(count)/1(clear)
b094
R/W 0 to 3
b095
R/W
b096
R/W 330 to 380, 660 to 760
b097
R/W
-
-
b100
R/W 0. to "free-setting V/f frequency (2)"
b101
R/W 0. to 8000
b102
R/W 0. to "free-setting V/f frequency (3)"
b103
R/W 0. to 8000
b104
R/W 0. to "free-setting V/f frequency (4)"
b105
R/W 0. to 8000
b106
R/W 0. to "free-setting V/f frequency (5)"
b107
R/W 0. to 8000
b108
R/W 0. to "free-setting V/f frequency (6)"
b109
R/W 0. to 8000
b110
R/W 0. to "free-setting V/f frequency (7)"
b111
R/W 0. to 8000
b112
R/W 0. to 400.
b113
R/W 0. to 8000
Monitoring and setting items
-
0. to 100. (%) or "no" (ignore)
0. to 100. (%) or "no" (ignore)
-
-
-
0,1 (clearing the trip history), 2 (initializing the
data), 3 (clearing the trip history and initializing the
data), 4 (clearing the trip history and initializing the
data and EzSQ program)
0 (starting with 0 Hz), 1 (starting with matching
frequency), 2 (starting with active matching
frequency)
0(disabling)/1(enabling( output current controlled))/
2(enabling( fin temperature controlled))
0 (always operating the fan), 1 (operating the fan
only during inverter operation [including 5 minutes
after power-on and power-off]) ,2
0 (disabling), 1 (enabling [disabling while the motor
is stopped]), 2 (enabling [enabling also while the
motor is stopped])
Min.Resistance to 6000
-
Ver.3− − − − 101
Data resolution
1 [%]
1 [%]
-
1 [° c]
-
-
1
-
0.01 [Hz]
0.1 [kHz]
-
-
0.01
-
-
-
0.1 [%]
-
-
-
-
1. [V]
0.1[ ]
-
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]