C− − − − 16
Func.
Code
Motor cable length
B033
parameter
Run/power ON warning time
b034
Rotation direction restriction
B035
Reduced voltage start
b036
selection
Function code display
b037
restriction
Initial display selection
b038
Automatic user parameter
B039
registration
Torque limit selection
B040
Torque limit 1 (fwd/power)
B041
Torque limit 2 (fwd/power)
b042
Torque limit 3 (rev/power)
B043
Torque limit 4 (fwd/regen.)
B044
Torque LAD STOP selection
b045
"b" Function
Name
Set range is 5 to 20.
Range is,
0.:Warning disabled
1. to 9999.:
10~99,990 hrs (unit: 10)
1000 to 6553:
100,000~655,350 hrs (unit: 100)
Three option codes:
00...No restriction
01...Reverse rotation is restricted
02...Forward rotation is restricted
Set range, 0 (disabling the
function), 1 (approx. 6ms) to 255
(approx. 1.5s)
Six option codes:
00...Full display
01...Function-specific display
02...User setting (and b037)
03...Data comparison display
04...Basic display
05...Monitor display only
000...Func. code that SET key
001~030...d001~d030 displayed
201...F001 displayed
202...B display of LCD operator
Two option codes:
00...Disable
01...Enable
Three option codes:
00...Quadrant-specific setting
01...Terminal-switching mode
02...Analog voltage input mode(O)
Torque limit level in forward
powering quadrant, range is 0 to
200%/no(disabled)
Torque limit level in forward
powering quadrant, range is 0 to
200%/no(disabled)
Torque
powering quadrant, range is 0 to
200%/no(disabled)
Torque limit level in forward
regen. quadrant, range is 0 to
200%/no(disabled)
Two option codes:
00...Disable
01...Enable
Description
pressed last displayed.(*)
mode
limit
level
in
Run
Mode
Defaults
Edit
A
B
Initial data Units
10.
0.
00
2
00
001
00
00
200
200
reverse
200
200
00
−
Hrs.
−
−
−
−
%
%
%
%