Hitachi WJ200-001S Instruction Manual page 272

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Electronic Thermal Warning Signal Output
You can configure this function so that the inverter outputs a warning signal before the
electronic thermal protection operates against motor overheat. You can also set the
threshold level to output a warning signal with the electronic thermal warning level
setting ().
To output the warning signal, assign function
output terminals [11] to [12], or to the relay output terminal.
Option
Terminal
Code
Symbol

THM
Thermal warning
signal output
11, 12, AL0 – AL2
Valid for inputs:

Required settings
Notes:
 The example circuit for terminal [11] drives a relay
coil. Note the use of a diode to prevent the
negative-going turn-off spike generated by the coil
from damaging the inverter's output transistor.
Function Name
State
ON
OFF
"
(THM)" to one of the intelligent
Description
Accumulated thermal level exceeds the electronic
thermal warning level ()
Accumulated thermal level does not exceed the
electronic thermal warning level ()
Example for terminal [11] (default output
configuration shown – see
Inverter output
terminal circuit
CM2
Example for terminal [AL0], [AL1], [AL2] (requires
output configuration – see
Inverter logic
circuit board
AL0
AL1
Power
supply
See I/O specs on
page 4-6
465
page
3-89):
THM
11
RY
page 4-51 and
3-91):
THM
AL2
Load