Multistage position switching function (CP1/CP2/CP3)
When functions " (CP1)" to " (CP3)" are assigned to input terminal [1] to [7] ( to
), you can select multistage positions 0 to 7. Preset position data 0 to 7 in to
. If no assignment is set in terminals, position command will be position-0 ().
Code
(Note 1) If =, set the number of pulse for one rotation in .
To avoid misinput due to time lag of each input, you can adjust the determination time
in (). The input status is taken the preset time () after the last change of input
status. (Note that a long determination time deteriorates the input response.)
Determination time
Position
command
CP1
CP2
CP3
Item
Multistage position 0
Multistage position 1
Multistage position 2
Multistage position 3
Multistage position 4
Multistage position 5
Multistage position 6
Multistage position 7
Position setting
Multistage position 0 ()
Multistage position 1 ()
Multistage position 2 ()
Multistage position 3 ()
Multistage position 4 ()
Multistage position 5 ()
Multistage position 6 ()
Multistage position 7 ()
()=
7
3
Determination time
() specified
1
ON
Determination time ()
Data or data range
P073 to P072
(Displayed higher
4-digits only)
CP3
CP2
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
5
4
ON
ON
3119
Description
(Note 1)
CP1
0
1
0
1
0
1
0
1