360
Func.
Code
Initial display selection
Frequency scaling
conversion factor
Display ex.operator
connected
1st parameter of Dual
Monitor
2nd parameter of Dual
Monitor
Frequency set in monitoring
Automatic return to the
initial display
Ex. operator com. loss action
(*) note: If the power is off with displaying "000" after the set, b038 comes when power is on
again.
"b" Function
Name
Func. code that SET key
~~ displayed
displayed
B display of LCD operator
Specify a constant to scale the
displayed frequency for
monitor, range is 0.01 to 99.99
When an external operator is
connected via RS-422 port, the
built-in display is locked and
shows only one "d" parameter
configured in:
~
Set any two "d" parameters in
b160 and b161, then they can be
monitored in d050. The two
parameters are switched by
up/down keys.
Set range: ~
Two option codes:
Freq. set disabled
Freq. set enabled
10 min. after the last key
operation, display returns to the
initial parameter set by .
Two option codes:
Disable
Enable
Five option codes:
Trip
Trip after deceleration to a
Ignore
Coasting (FRS)
Decelerates to a stop
Description
pressed last displayed.(*)
stop
Run
Defaults
Mode
Initial data
Units
Edit
001
1.00
001
001
002
00
00
02