Func.
Name
Code
Torque command input
selection
Torque command level
input
Torque bias mode selection
Torque bias value setting
Torque bias polar selection
Speed limit of Torque
control
(Forward rotation)
Speed limit of Torque
control
(Forward rotation)
Speed / Torque control
switching time
Communication watchdog
timer
(for option)
Inverter action on
communication error
(for option)
DeviceNet polled I/O:
Output instance number
Inverter action on
communication idle mode
Motor poles setting for
RPM
Pulse train input frequency
scale setting
Pulse train input frequency
filter time constant setting
Pulse train input bias
setting
Limitation of the pulse
train input setting
Multistage position 0
Multistage position 1
Multistage position 2
Multistage position 3
Multistage position 4
Multistage position 5
"P" Function
Description
Four option codes:
...Analog voltage input [O]
...Analog current input [OI]
...Operator, ...Option
Set range is 0~200%
Two option codes:
...No bias
...Operator
Range is –200~200%
Three option codes:
...According to the sign
...According to the rotation direction
...Option
Set range is 0.00~120.00Hz
Set range is 0.00~120.00Hz
Set range is 0 to 1000 ms.
Set range is 0.00 to 99.99 seconds.
(tripping),
(tripping after decelerating and
stopping the motor),
(ignoring errors),
(stopping the motor after
free-running),
(decelerating and stopping the motor)
0 to 20
(tripping),
(tripping after decelerating and
stopping the motor),
(ignoring errors),
(stopping the motor after
free-running),
(decelerating and stopping the
motor)
0/2/4/6/8/10/12/14/16/18/20/22/24/26/28/
30/32/34/36/38/40/42/44/46/48
Sets the pulse numbers at max.
frequency, set range is 1.0~32.0 kHz
Set range is 0.01~2.00 seconds.
Set range is –100~100 %
Set range is 0~100 %
P073 to P072
(Displayed higher 4-digits only)
Ver.277
Run
Mode
Defaults
Edit
A
B
Initial data
00
0.
00
0.
00
0.00
0.00
0.
1.00
00
01
00
0
1.5
0.10
0.
100.
0
0
0
0
0
0
Units
%
%
Hz
Hz
ms
s
Poles
kHz
s
%
%
Pulses
Pulses
Pulses
Pulses
Pulses
Pulses