Option
Terminal
Code
Symbol
BOK
Brake confirmation
LAC
LAD cancellation
PCLR
Pulse counter clear
ADD
ADD frequency enable ON
F-TM
Force Terminal Mode
ATR
Enable torque
command input
KHC
Clear watt-hour data
MI1
General purpose input
(1)
MI2
General purpose input
(2)
MI3
General purpose input
(3)
MI4
General purpose input
(4)
MI5
General purpose input
(5)
MI6
General purpose input
(6)
MI7
General purpose input
(7)
AHD
Analog command hold
CP1
Multistage-position
switch (1)
CP2
Multistage-position
switch (2)
CP3
Multistage-position
switch (3)
ORL
Limit signal of homing
ORG
Trigger signal of
homing
SPD
Speed/position
changeover
Input Function Summary Table
Function Name
ON
OFF Brake wait time () is not valid
ON
OFF Accel. and/or decel. is according to the set ramp time
ON
OFF Maintain the position deviation data
OFF Does not add the value to the output frequency
ON
OFF Source of output frequency set by and source of
ON
OFF Torque control command input is disabled
ON
OFF No action
ON
OFF General purpose input (1) is made OFF under EzSQ
ON
OFF General purpose input (2) is made OFF under EzSQ
ON
OFF General purpose input (3) is made OFF under EzSQ
ON
OFF General purpose input (4) is made OFF under EzSQ
ON
OFF General purpose input (5) is made OFF under EzSQ
ON
OFF General purpose input (6) is made OFF under EzSQ
ON
OFF General purpose input (7) is made OFF under EzSQ
ON
OFF Analog command is not held
ON
OFF
ON
OFF
ON
OFF
ON
OFF Limit signal of homing is OFF
ON
OFF No action
ON
OFF Position control mode
Description
Brake wait time () is valid
Set ramp times are ignored. Inverter output
immediately follows the freq. command.
Clear the position deviation data
Adds the (add frequency) value to the output
frequency
Force inverter to use input terminals for output
frequency and Run command sources
Run command set by is used
Torque control command input is enabled
Clear watt-hour data
General purpose input (1) is made ON under EzSQ
General purpose input (2) is made ON under EzSQ
General purpose input (3) is made ON under EzSQ
General purpose input (4) is made ON under EzSQ
General purpose input (5) is made ON under EzSQ
General purpose input (6) is made ON under EzSQ
General purpose input (7) is made ON under EzSQ
Analog command is held
Multistage position commands are set according to
the combination of these switches.
Limit signal of homing is ON
Starts homing operation
Speed control mode
387