Hitachi WJ200-001S Instruction Manual page 371

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

B36
Parameter group B
Register
Function name
No.
Restart mode on power
1301h
failure / under-voltage trip
Allowable under-voltage
1302h
power failure time
Retry wait time before
1303h
motor restart
Instantaneous power
1304h
failure/under-voltage trip
alarm enable
Number of restarts on
1305h
power failure/under-voltage
trip events
1306h
(Reserved)
1307h
Restart frequency threshold
1308h
Restart mode on over
1309h
voltage / over current
130Ah
(Reserved)
Number of retry on over
130Bh
voltage / over current
Retry wait time on over
130Ch
voltage / over current
130Dh
Level of electronic thermal
Electronic thermal
130Eh
characteristic
130Fh
(Reserved)
Free setting, electronic
1310h
thermal frequency (1)
Free setting, electronic
1311h
thermal current (1)
Free setting, electronic
1312h
thermal frequency (2)
Free setting, electronic
1313h
thermal current (2)
Free setting, electronic
1314h
thermal frequency (3)
Free setting, electronic
1315h
thermal current (3)
Overload restriction
1316h
operation mode
1317h
Overload restriction level
Deceleration rate at
1318h
overload restriction
Overload restriction
1319h
operation mode (2)
131Ah
Overload restriction level 2
Deceleration rate at
131Bh
overload restriction (2)
Overcurrent suppression
131Ch
enable
Current level of active freq.
131Dh
matching
Deceleration rate of active
131Eh
freq. matching
Function code
R/W
0 (tripping), 1 (starting with 0 Hz), 2 (starting
with matching frequency), 3 (tripping after
b001
R/W
deceleration and stopping with matching
frequency), 4 (restarting with active matching
frequency)
b002
R/W 3 to 250
b003
R/W 3 to 1000
0 (disabling), 1 (enabling), 2 (disabling during
b004
R/W
stopping and decelerating to stop)
b005
R/W 0 (16 times), 1 (unlimited)
-
-
-
b007 (high)
R/W
0 to 40000
b007 (low)
R/W
0 (tripping), 1 (starting with 0 Hz), 2 (starting
with matching frequency), 3 (tripping after
b008
R/W
deceleration and stopping with matching
frequency), 4 (restarting with active matching
frequency)
-
-
-
b010
R/W 1 to 3
b011
R/W 3 to 1000
b012
R/W 200 to 1000
0 (reduced-torque characteristic), 1
b013
R/W
(constant-torque characteristic), 2 (free
setting)
-
-
Inaccessible
b015
R/W 0 to 400
b016
R/W 0 to Rated current
b017
R/W 0 to 400
b018
R/W 0 to Rated current
b019
R/W 0 to 400
b020
R/W 0 to Rated current
0 (disabling), 1 (enabling during acceleration
and constant-speed operation), 2 (enabling
b021
R/W
during constant-speed operation), 3 (enabling
during acceleration and constant-speed
operation [speed increase at regeneration])
b022
R/W 200 to 2000
b023
R/W 1 to 30000
0 (disabling), 1 (enabling during acceleration
and constant-speed operation), 2 (enabling
b024
R/W
during constant-speed operation), 3 (enabling
during acceleration and constant-speed
operation [speed increase at regeneration])
b025
R/W 200 to 2000
b026
R/W 1 to 30000
b027
R/W 0 (disabling), 1 (enabling)
b028
R/W 100 to 2000
b029
R/W 1 to 30000
Monitoring and setting items
Data
resolution
-
0.1 [sec.]
0.1 [sec.]
-
-
-
0.01 [Hz]
-
-
1 [time]
0.1 [sec.]
0.1 [%]
-
-
1 [Hz]
0.1 [A]
1 [Hz]
0.1 [A]
1 [Hz]
0.1 [A]
-
0.1 [%]
sec.
0.1 [
]
-
0.1 [%]
0.1 [
sec.
]
-
0.1 [%]
0.1 [
sec.
]

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents