Ver.24
14.1.3 PM mode switching
It changes to the PM mode by setting the initialization trigger (b180) to 01 after setting the inverter mode
selection (b171) to 03, and initialization is executed.
■When using this mode, observe the following precautions.
① hen 01 is set on the initialization trigger (b180), and SET key is pressed, initialization starts immediately
and there is not any way to restore the previous parameter setting.
② All data will be initialized regardless the setting of b094. b094
③ The settings of "P100" to "P131", running-time data, and power-on time data cannot be cleared.
④ When display is restricted by the function code display restriction function (b037) or software is locked by
the software lock function (b031), you cannot initialize because the function codes of initialization are
no-display. If you forget password that restrict setting (b031) and (b037), you cannot cancel it. (So you
cannot initialize when software lock is active, you note that the setting password. (See section 7.6.11 the
password function.))
Item
Inverter mode selection
Initialization trigger
Function code
Data or range of data
00
b171
03
00
b180
01
Description
No
PM mode
No action
Initialize