Hitachi WJ200-001S Instruction Manual page 493

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Ver.264
Func.
Code
[AM] terminal selection

(Analog voltage output
0...10V)
Digital current monitor

reference value
Output [11] active state

Output [12] active state

Alarm relay active state

Output mode of low current

detection
Low current detection level

Output mode of overload

warning
Overload warning level

Overload warning level, 2

motor
Frequency arrival setting for

acceleration
Frequency arrival setting for

deceleration
PID deviation level

Frequency arrival setting 2

for acceleration
Frequency arrival setting 2

for deceleration
Pulse train input/output

scale conversion
PID FBV output

high limit
"C" Function
Name
11 programmable functions:
Output frequency
Output current
Output torque
Output voltage
Input power
Electronic thermal load ratio
LAD frequency
Heat sink temperature
Output torque (with code)
General output
Option
Current with digital current monitor
output at 1,440Hz
Range is 20%~200% of rated current
Select logic conversion, two option codes:
normally open [NO]
normally closed [NC]
Two option codes:
During acceleration, deceleration
and constant speed
During constant speed only
Set the level of low load detection, range
is 0.0 to 2.0*inverter rated current
Two option codes:
During accel., decel. and constant
speed
During constant speed only
Sets the overload warning signal level
between 0% and 200% (from 0 to two time
the rated current of the inverter)
Sets the overload warning signal level
nd
between 0% and 200% (from 0 to two time
the rated current of the inverter)
Sets the frequency arrival setting
threshold for the output frequency during
acceleration,
range is 0.0 to 400.0 Hz
Sets the frequency arrival setting
threshold for the output frequency during
deceleration,
range is 0.0 to 400.0 Hz
Sets the allowable PID loop error
magnitude (absolute value), SP-PV, range
is 0.0 to 100%
Set range is 0.0 to 400.0 Hz
Set range is 0.0 to 400.0 Hz
If EO terminal is configured as pulse
train input (C027=15), scale conversion is
set in C047.
Pulse-out = Pulse-in  (C047)
Set range is 0.01 to 99.99
When the PV exceeds this value, the PID
loop turns OFF the PID second stage
output, range is 0.0 to 100%
Description
Run
Mode
Defaults
Edit
A
B
Initial data
Units
07
[LAD]
Rated
current
00
00
01
01
INV rated
current
01
Rated
current
x 1.15
Rated
current
x 1.15
0.00
Hz
0.00
Hz
3.0
0.00
Hz
0.00
Hz
1.00
100.0
A
A
A