example wiring diagrams are in "Using Intelligent Output Terminals" in chapter 4.
Option
Terminal
Function Name
Code
Symbol
RUN
Run Signal
FA1
Frequency Arrival
Type 1–Constant
Speed
FA2
Frequency Arrival
Type 2–Over frequency
OL
Overload Advance
Notice Signal 1
OD
Output Deviation for
PID Control
AL
Alarm Signal
FA3
Frequency Arrival
Type 3–Set frequency
OTQ
Over/under Torque
Signal
UV
Undervoltage
TRQ
Torque Limited Signal
RNT
Run Time Expired
ONT
Power ON time
Expired
THM
Thermal Warning
BRK
Brake Release Signal
BER
Brake Error Signal
ZS
Zero Hz Speed
Detection Signal
DSE
Speed Deviation
Excessive
POK
Positioning Completion ON
FA4
Frequency Arrival
Type 4–Over frequency
FA5
Frequency Arrival
Type 5–Set frequency
Output Function Summary Table
ON
When the inverter is in Run Mode
OFF
When the inverter is in Stop Mode
ON
When output to motor is at the set frequency
When output to motor is OFF, or in any acceleration or
OFF
deceleration ramp
When output to motor is at or above the set freq., even if in
ON
accel () or decel () ramps
When output to motor is OFF, or at a level below the set
OFF
frequency
When output current is more than the set threshold () for
ON
the overload signal
When output current is less than the set threshold for the
OFF
deviation signal
When PID error is more than the set threshold for the
ON
deviation signal
When PID error is less than the set threshold for the
OFF
deviation signal
ON
When an alarm signal has occurred and has not been cleared
When no alarm has occurred since the last cleaning of
OFF
alarm(s)
When output to motor is at the set frequency, during accel
ON
() and decel ().
When output to motor is OFF, or is not at a level of the set
OFF
frequency
ON
Estimated motor torque exceeds the specified level
OFF
Estimated motor torque is lower than the specified level
ON
Inverter is in Undervoltage
OFF
Inverter is not in Undervoltage
ON
Torque limit function is executing
OFF
Torque limit function is not executing
ON
Total running time of the inverter exceeds the specified value
Total running time of the inverter does not exceed the
OFF
specified value
Total power ON time of the inverter exceeds the specified
ON
value
Total power ON time of the inverter does not exceed the
OFF
specified value
ON
Accumulated thermal count exceeds the set value
Accumulated thermal count does not exceed the set
OFF
value
ON
Output for brake release
OFF
No action for brake
ON
Brake error has occurred
OFF
Brake performance is normal
ON
Output frequency falls below the threshold specified in
Output frequency is higher than the threshold specified in
OFF
Deviation of speed command and actual speed exceeds the
ON
specified value .
Deviation of speed command and actual speed does not exceed
OFF
the specified value .
Positioning is completed
OFF
Positioning is not completed
When output to motor is at or above the set freq., even if in
ON
accel () or decel () ramps
When output to motor is OFF, or at a level below the set
OFF
frequency
When output to motor is at the set frequency, during accel
ON
() and decel ().
When output to motor is OFF, or is not at a level of the set
OFF
frequency
Description
Ver.271