Force Operation from Digital Operator
This function permits a digital operator interface to override the following two settings
in the inverter:
- Frequency source
- Run command source
When using the [OPE] terminal input, typically A001 and
sources other than the digital operator interface for the output frequency and Run
command sources, respectively. When the [OPE] input is ON, then user has immediate
command of the inverter, to start or stop the motor and to set the speed.
Option
Terminal
Code
Symbol
OPE
Force Operation
from Digital
Operator
~
Valid for inputs:
Required settings
Notes:
When changing the [OPE] state during Run Mode
(inverter is driving the motor), the inverter will stop
the motor before the new [OPE] state takes effect.
If the [OPE] input turns ON and the digital
operator gives a Run command while the inverter
is already running, the inverter stops the motor.
Then the digital operator can control the motor.
Function Name
State
ON
OFF
(set not equal to )
(set not equal to )
Description
Forces the operator interface to override:
- Frequency Source Setting, and
Command Source Setting
Parameters
and
for the frequency source and the Run command
source, respectively
Example (default input configuration shown—see
page
3-85):
7
6
5
4
See I/O specs on
page 4–6.
435
are configured for
- Run
are in effect again,
OPE