Undervoltage Signal
The inverter outputs the undervoltage signal when it detects that the inverter is in
undervoltage situation.
To enable this function, assign
Option
Terminal
Code
Symbol

UV
Valid for inputs:
Required settings
Notes:
 The example circuit for terminal [11] drives a relay
coil. Note the use of a diode to prevent the
negative-going turn-off spike generated by the coil
from damaging the inverter's output transistor.
"
Function Name
State
Undervoltage signal
11, 12, AL0 – AL2
(UV)" to an intelligent output terminal.
ON
Inverter is in undervoltage
OFF
Inverter is in normal condition
Example for terminal [11] (default output
configuration shown – see
Inverter output
terminal circuit
Example for terminal [AL0], [AL1], [AL2] (requires
output configuration – see
Inverter logic
circuit board
AL0
Power
supply
See I/O specs on
Description
page
3-89):
UV
CM2
11
RY
page 4-51 and
3-91):
UV
AL1
AL2
Load
page 4-6