52
Introduction
Introduction
A motor control system will obviously include a motor and inverter, as well as fuses for
safety. If you are connecting a motor to the inverter on a test bench just to get started,
that's all you may need for now. But a fully developed system can also have a variety of
additional components. Some can be for noise suppression, while others may enhance
the inverter's braking performance. The figure below shows a system with several
possible optional components, and the table gives part number information.
From power supply
Breaker,
MCCB or
GFI
AC reactor
(Input choke)
RF noise filter
EMI filter
Capacitive
L1
L2
L3
+1
Inverter
+
-
GND
T1
T2
T3
RF noise filter
AC reactor
(Input choke)
or LCR filter
Motor
Thermal
switch
AC reactor, input side
RF noise filter, input side
EMI filter (for CE)
Capacitive filter
DC link choke
Braking resistor
Braking resistor
NEMA-rated
Braking unit
RF noise filter, output side
AC reactor, output side
LCR filter
filter
NOTE: The Hitachi part number series for accessories
DC link
includes different sizes of each part type, specified by the
choke
–x suffix. Hitachi product literature can help match size
and rating of your inverter to the proper accessory size.
Braking
Unit
Each inverter accessory comes with its own printed
instruction manual. Please refer to those manuals for
complete installation details. This chapter gives only an
overview of these optional system devices.
Name
EU, Japan
ALI-xxx2
ZCL-xxx
CFI-x
DCL-x-xx
JRB-xxx-x
SRB-xxx-x
BRD-xxx
ZCL-xxx
ACL-x2-xxx
Combination:
ACL-x2-xxx
LPF-xxx
R-2-xxx
Part No. Series
USA
HRL-x
ZCL-xxx
(to be fixed)
CFI-x
HDC-xxx
JRB-xxx-x
SRB-xxx-x
HRB-x,
NSRBx00-x
NJRB-xxx
BRD-xxx
ZCL-xxx
HRL-xxx
HRL-xxC
See
page
5-3
5-4
5-4
5-4
5-5
5-5
5-5
5-5
5-4
5-3