Ver.276
Func.
Code
PM Initial Magnet
Position Estimation 0V
Wait Times
PM Initial Magnet
Position Estimation
Detect Wait Times
PM Initial Magnet
Position Estimation
Detect Times
PM Initial Magnet
Position Estimation
Voltage Gain
H102 to H134 are displayed only when PM mode. PM mode only.
Expansion Card Functions
"P" parameters will be appeared when the expansion option is connected.
NOTE:. Mark "" in A line of [ Run Mode Edit] shows the accessible parameters when b031 is not set "10",
high level access.
NOTE:. Mark "" in B line of [ Run Mode Edit] shows the accessible parameters when b031 is set "10",
high level access
Func.
Code
Reaction when option card
error occurs
[EA] terminal selection
Pulse train input mode
selection for feedback
Encoder pulse setting
Simple positioning
selection
Creep Speed
Over-speed error detection
level
Speed deviation error
detection level
Deceleration time Input
Type
"H" Function
Name
0-255
0-255
0-255
0-200
"P" Function
Name
Two option codes:
...Inverter trips
...Ignores the error (Inverter
continues operation)
Three option codes:
...Speed reference (incl. PID)
...For control with encoder feedback
...Extended terminal for EzSQ
Four option codes:
...Single-phase pulse [EA]
...2-phase pulse (90 difference) 1
([EA] and [EB])
...2-phase pulse (90 difference) 2
([EA] and [EB])
...Single-phase pulse [EA] and
direction signal [EB]
Sets the pulse number (ppr) of the
encoder, set range is 32~1024 pulses
Two option codes:
...simple positioning deactivated
...simple positioning activated
Set range is start frequency ()
~10.00 Hz
Set range is 0~150%
Set range is 0~120 Hz
...Operator,...EzSQ
Description
Description
Run
Mode
Defaults
Edit
A
B
Initial data
10
10
30
100
Run
Mode
Defaults
Edit
A
B
Initial data
00
00
00
512.
00
5.00
115.0
10.00
00
Units
Units
Hz
%
Hz