466
External Brake Related Output Signals
These signals are used with brake control function.
To output the warning signals, assign function
intelligent output terminals [11] and [12], or to the relay output terminal.
Refer to chapter 3 for detailed explanation of the brake control function.
Option
Terminal
Code
Symbol

BRK

BER
Valid for inputs:
Required settings
Notes:
 The example circuit for terminal [11] drives a relay
coil. Note the use of a diode to prevent the
negative-going turn-off spike generated by the coil
from damaging the inverter's output transistor.
Function Name
State
Brake release signal
Brake error signal
11, 12, AL0 – AL2
~
"
(BRK)" and
ON
Brake is ready to be released
OFF
Brake is not ready to be released
ON
Brake error has occurred
OFF
Brake is working properly
Example for terminal [11] (default output
configuration shown – see
Inverter output
terminal circuit
Example for terminal [AL0], [AL1], [AL2] (requires
output configuration – see
Inverter logic
circuit board
AL0
Power
supply
See I/O specs on
"
(BER)" to the
Description
page
3-89):
BRK/BER
CM2
11
RY
page 4-51 and
3-91):
BRK/BER
AL1
AL2
Load
page 4-6