Intelligent Terminal Functions
NOTE:. Mark "" in A line of [ Run Mode Edit] shows the accessible parameters when b031 is not set "10",
high level access.
NOTE:. Mark "" in B line of [ Run Mode Edit] shows the accessible parameters when b031 is set "10",
high level access
Func.
Name
Code
Input [1] function
Input [2] function
Input [3] function
[GS1 assignable]
Input [4] function
[GS2 assignable]
Input [5] function
[PTC assignable]
Input [6] function
Input [7] function
Input [1] active state
Input [2] active state
Input [3] active state
Input [4] active state
Input [5] active state
Input [6] active state
Input [7] active state
Output [11] function
[EDM assignable]
Output [12] function
Alarm relay function
[EO] terminal selection
(Pulse/PWM output)
"C" Function
Description
Select input terminal [1] function, 68
options (see next section)
Select input terminal [2] function, 68
options (see next section)
Select input terminal [3] function, 68
options (see next section)
Select input terminal [4] function, 68
options (see next section)
Select input terminal [5] function, 68
options (see next section)
Select input terminal [6] function, 68
options (see next section)
Select input terminal [7] function, 68
options (see next section)
Select logic conversion, two option codes:
normally open [NO]
normally closed [NC]
48 programmable functions available for
logic (discrete) outputs
(see next section)
48 programmable functions available for
logic (discrete) outputs
(see next section)
13 programmable functions:
Output frequency (PWM)
Output current (PWM)
Output torque (PWM)
Output frequency (Pulse train)
Output voltage (PWM)
Input power (PWM)
Electronic thermal load ratio (PWM)
LAD frequency (PWM)
Output current (Pulse train)
Heat sink temperature (PWM)
General output (PWM)
Pulse train input monitor
Option(PWM)
Ver.263
Run
Mode
Defaults
Edit
A
B
Initial data
Units
00
[FW]
01
[RV]
12
[EXT]
18
[RS]
02
[CF1]
03
[CF1]
06
[JG]
00
00
00
00
00
00
00
00
[RUN]
01
[FA1]
05
[AL]
07
[LAD]