Hitachi WJ200-001S Instruction Manual page 224

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Multi-Speed Select ~Binary Operation
The inverter can store up to 16 different target
frequencies (speeds) that the motor output uses for
steady-state
accessible
through
intelligent terminals as binary-encoded inputs CF1 to
CF4 per the table to the right. These can be any of the
six inputs, and in any order. You can use fewer inputs
if you need eight or fewer speeds.
NOTE: When choosing a subset of speeds to use,
always start at the top of the table, and with the
least-significant bit: CF1, CF2, etc.
Speed
3rd
7th
5th
2nd
1st
6th
4th
0th
1
[CF1]
0
1
[CF2]
0
1
[CF3]
0
1
[FW]
0
Option
Terminal
Code
Symbol

CF1
Multi-speed Select,
Bit 0 (LSB)

CF2
Multi-speed Select,
Bit 1

CF3
Multi-speed Select,
Bit 2

CF4
Multi-speed Select,
Bit 3 (MSB)
~
Valid for inputs:
, =,
Required settings

Notes:
 When programming the multi-speed settings, be
sure to press the SET key each time and then set
the next multi-speed setting. Note that when the
key is not pressed, no data will be set.
 When a multi-speed setting more than 50Hz
(60Hz) is to be set, it is necessary to program the

maximum frequency
that speed
run
condition.
These
programming
Function Name
State
ON
OFF
ON
OFF
ON
OFF
ON
OFF
to

high enough to allow
Multi-
speed
speeds
are
Speed 0
four
of
the
Speed 1
Speed 2
Speed 3
Speed 4
Speed 5
Speed 6
Speed 7
Speed 8
Speed 9
Speed 10
Speed 11
Speed 12
Speed 13
Speed 14
Speed 15
The example with eight speeds in the
figure below shows how input switches
configured for CF1–CF3 functions can
change the motor speed in real time.
NOTE: Speed 0 depends on
parameter value.
Description
Binary encoded speed select, Bit 0, logical 1
Binary encoded speed select, Bit 0, logical 0
Binary encoded speed select, Bit 1, logical 1
Binary encoded speed select, Bit 1, logical 0
Binary encoded speed select, Bit 2, logical 1
Binary encoded speed select, Bit 2, logical 0
Binary encoded speed select, Bit 3, logical 1
Binary encoded speed select, Bit 3, logical 0
Example (some CF inputs require input
configuration; some are default inputs):
CF4 CF3 CF2 CF1
7
6
5
4
See I/O specs on
page 4–6.
Input Function
CF4 CF3 CF2 CF1
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
1
0
1
1
1
1
0
0
1
1
0
1
1
1
1
0
1
1
1
1
3
2
1
L
P24
PLC
417


Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents