Output Function Summary Table – This table shows all functions for the logical outputs
(terminals [11], [12] and [AL]) at a glance. Detailed descriptions of these functions,
related parameters and settings, and example wiring diagrams are in "Using Intelligent
Output Terminals" in chapter 4.
Option
Terminal
Code
Symbol
RUN
Run Signal
FA1
Frequency Arrival Type
1–Constant Speed
FA2
Frequency Arrival Type
2–Over frequency
OL
Overload Advance
Notice Signal 1
OD
Output Deviation for PID
Control
AL
Alarm Signal
FA3
Frequency Arrival Type
3–Set frequency
OTQ
Over/under Torque
Signal
UV
Undervoltage
TRQ
Torque Limited Signal
RNT
Run Time Expired
ONT
Power ON time Expired
THM
Thermal Warning
BRK
Brake Release Signal
BER
Brake Error Signal
ZS
Zero Hz Speed
Detection Signal
Output Function Summary Table
Function Name
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Description
When the inverter is in Run Mode
When the inverter is in Stop Mode
When output to motor is at the set frequency
When output to motor is OFF, or in any acceleration
or deceleration ramp
When output to motor is at or above the set freq.,
even if in accel () or decel () ramps
When output to motor is OFF, or at a level below the
set frequency
When output current is more than the set threshold
() for the overload signal
When output current is less than the set threshold
for the deviation signal
When PID error is more than the set threshold for
the deviation signal
When PID error is less than the set threshold for the
deviation signal
When an alarm signal has occurred and has not
been cleared
When no alarm has occurred since the last cleaning
of alarm(s)
When output to motor is at the set frequency, during
accel () and decel ().
When output to motor is OFF, or is not at a level of
the set frequency
Estimated motor torque exceeds the specified level
Estimated motor torque is lower than the specified
level
Inverter is in Undervoltage
Inverter is not in Undervoltage
Torque limit function is executing
Torque limit function is not executing
Total running time of the inverter exceeds the
specified value
Total running time of the inverter does not exceed
the specified value
Total power ON time of the inverter exceeds the
specified value
Total power ON time of the inverter does not exceed
the specified value
Accumulated thermal count exceeds the set
value
Accumulated thermal count does not exceed the
set value
Output for brake release
No action for brake
Brake error has occurred
Brake performance is normal
Output frequency falls below the threshold specified
in
391