Hitachi WJ200-001S Instruction Manual page 137

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

352
Func.
Code
Overload restriction

operation mode
Overload restriction

operation mode, 2
Overload restriction level

Overload restriction level,

2
motor
nd
Deceleration rate at

overload restriction
Deceleration rate at

overload restriction, 2
motor
Overload restriction

operation mode 2
Overload restriction level 2

Deceleration rate 2 at

overload restriction
OC suppression selection *

"b" Function
Name
Select the operation mode during
overload conditions, four options,
option codes:
Disabled
Enabled for acceleration and
constant speed
Enabled for constant speed
only
Enabled for acceleration and
constant speed, increase speed
at regen.
motor
nd
Sets the level of overload
restriction, between 20% and 200%
of the rated current of the inverter,
setting resolution is 1% of rated
current
Sets the deceleration rate when
inverter detects overload, range is
0.1 to 3000.0, resolution 0.1
nd
Select the operation mode during
overload conditions, four options,
option codes:
Disabled
Enabled for acceleration and
constant speed
Enabled for constant speed
only
Enabled for acceleration and
constant speed, increase speed
at regen.
Sets the level of overload
restriction, between 20% and 200%
of the rated current of the inverter,
setting resolution is 1% of rated
current
Sets the deceleration rate when
inverter detects overload, range is
0.1 to 3000.0, resolution 0.1
Two option codes:
Disabled
Enabled
Description
Run
Defaults
Mode
Initial data
Units
Edit
01
01
Rated
Amps
current
x 1.5
Rated
Amps
current
x 1.5
1.0
sec.
1.0
sec.
01
Rated
Amps
current
x 1.5
1.0
sec.
00

Advertisement

Table of Contents

Troubleshooting

loading