Simple positioning (current position store at shut down)
I n the case of P081 = 01 of the new addition, the inverter stores a current position (inside 4 multiply data) into
P082 on the EEPROM at the time of power supply shut down. And at the time of power activation, the inverter
set a value of P082 into a current position inside level.
P lease handle P082 as Read Only parameter
Simple positioning (preset function by PSET terminal)
W hen input terminal function, "PSET(91) which added newly as a set range of C001 ~ C007 " is ON,
the inverter set a value of (P083 *4) into a current position inside level.
Here, P083 is the value that is not 4 multiply like a position command.
T his function is effective about P075( Positioning Mode Selection) = 00.
In addition, it is effective about both of P012 (simple positioning selection) = 00 (invalid) or 02 (valid).