Func.
Name
Code
Motor constant I0,
H233
motor (Auto tuned data)
2
nd
Motor constant J
H034
(Auto tuned data)
Motor constant J,
H234
2
motor (Auto tuned data)
nd
Slip compensation P gain
H050
for V/f control with FB
Slip compensation I gain
H051
for V/f control with FB
Expansion Card Functions
"P" parameters will be appeared when the expansion option is connected.
Func.
Name
Code
Reaction when option card
P001
error occurs
[EA] terminal selection
P003
Pulse train input mode
P004
selection for feedback
Encoder pulse setting
P011
Simple positioning selection
P012
Creep Speed
p015
Over-speed error detection
P026
level
Speed deviation error
P027
detection level
Deceleration time Input
P031
Type
"H" Function
Description
0.001~9999 kgm
0.00-10.00
0.-1000.
"P" Function
Description
Two option codes:
00...Inverter trips
01...Ignores the error (Inverter
continues operation)
Three option codes:
00...Speed reference (incl. PID)
01...For control with encoder
feedback
02...Extended terminal for EzSQ
Four option codes:
00...Single-phase pulse [EA]
01...2-phase pulse (90°
difference) 1 ([EA] and [EB])
02...2-phase pulse (90°
difference) 2 ([EA] and [EB])
03...Single-phase pulse [EA] and
direction signal [EB]
Sets the pulse number (ppr) of
the encoder, set range is 32~1024
pulses
Two option codes:
00...simple positioning
deactivated
01...simple positioning activated
Set range is start frequency
(b082) ~10.00 Hz
Set range is 0~150%
Set range is 0~120 Hz
00...Operator, 01...EzSQ
Run
Mode
Edit
A B
2
Run
Mode
Edit
A
C− − − − 29
Defaults
Initial
Units
data
A
kgm
2
kgm
2
0.20
Times
2.
(s)
Defaults
Initial
B
Units
data
00
-
00
-
00
-
512.
-
00
-
5.00
Hz
115.0
%
10.00
Hz
00

Advertisement