Ver.3.1− − − − 4
Addition of special monitor display and error
The set range of b145 has been expanded to support a new special monitor and error display.
In the expanded setting of b145, the signal states of EDM, GS1 and GS2 are monitored and special monitor
display content or error code is showed on keypad in accordance with table Ver.3.1-5.
<CAUTION>
This additional monitor function is just a supplementary display function. A whole system
must be designed and configured in accordance with the instructions in Appendix E.
b146 can adjust the delay time that specifies time to transit from state (4) to state(7) depicted in fig.
Ver.3.1-2. This parameter is valid only when b145=05. Once the state transits to state (7) in fig. Ver.3.1-2, it
is necessary to active (open) both GS1 and GS2 again (to state (2)), and then deactivate (close) both GS1 and
GS2 in order to return to normal operation (state (1)).
Func.
Func.
Func.
Func.
Code
Code
Code
Code
b145
b1
45
GS input mode select
b1
b1
45
45
b146
b146
b146
b146
Delay time of release
operation
Name
Name
Name
Name
00 - - - - 05
00
05
00
00
05
05
Displays special monitor display
content and error specified in table
Ver.3.1-5. Please refer to table
Ver3.1-5.
Valid only when b145 = 05,
range is 0.00 to 2.00 sec.
Table Ver.3.1-3
Description
Description
Description
Description
A A A A B B B B
Modbus register
Modbus
register
Modbus
Modbus
register
register
Initial data
Initial data
Initial data
Initial data
number
number
number
number
00
1394h
0.00
1395h
Resolution
Resolution
Resolution
Resolution
-
0.01 [sec]