Hitachi WJ200-001S Instruction Manual page 408

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Func.
Name
Code
1st parameter of Dual
b160
Monitor
2nd parameter of Dual
b161
Monitor
Frequency set in monitoring
b163
Automatic return to the
b164
initial display
Ex. operator com. loss action
b165
Data Read/Write select
b166
Inverter mode selection
b171
Initialization trigger
b180
(*)
b190
Password Settings A
Password authentication A
b191
Password Settings B
b192
Password authentication B
b193
"b" Function
Description
Set any two "d" parameters in b160
and b161, then they can be
monitored in d050. The two
parameters are switched by
up/down keys.
Set range: d001 ~ d030
Two option codes:
00...Freq. set disabled
01...Freq. set enabled
10 min. after the last key
operation, display returns to the
initial parameter set by b038. Two
option codes:
00...Disable
01...Enable
Five option codes:
00...Trip
01...Trip after deceleration to a
stop
02...Ignore
03...Coasting (FRS)
04...Decelerates to a stop
00... Read/Write OK
01... Protected
Three option codes:
00...No function
01...Std. IM (Induction Motor)
03...PM(Permanent Magnet
Motor)
This is to perform initialization by
parameter input with b084, b085
and b094. Two option codes:
00...Initialization disable
01...Perform initialization
0000(Invalid Password)
0001-FFFF(Password)
0000-FFFF
0000(Invalid Password)
0001-FFFF(Password)
0000-FFFF
C− − − − 21
Run
Mode
Defaults
Edit
A
B
Initial data Units
001
002
00
-
00
-
02
-
00
00
-
00
-
0000
-
0000
-
0000
-
0000
-