PM Motor Constants Functions
NOTE:. Mark "" in A line of [ Run Mode Edit] shows the accessible parameters when b031 is not set "10",
high level access.
NOTE:. Mark "" in B line of [ Run Mode Edit] shows the accessible parameters when b031 is set "10",
high level access
Func.
Name
Code
PM motor code setting
PM motor capacity
PM motor pole setting
PM Rated Current
PM const R(Resistance)
PM const Ld(d-axis
inductance)
PM const Lq(q-axis
inductance)
PM const Ke(Induction
voltage constant)
PM const J(Moment of
inertia)
PM const R (Resistance,
Auto)
PM const Ld(d-axis
inductance, Auto)
PM const Lq(q-axis
inductance, Auto)
PM Speed Response
PM Starting Current
PM Starting Time
PM Stabilization Constant
PM Minimum Frequency
PM No-Load Current
PM Starting Method
Select
"H" Function
Description
Hitachi standard
(Use H106-H110 at motor
constants)
Auto-Tuning
(Use H109-H110, H111-H113 at
motor constants)
0.1/0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.0/3.7/
4.0/5.5/7.5/11.0/15.0/18.5
2/4/6/8/10/12/14/16/18/20/22/24/26/28/
30/32/34/36/38/40/42/44/46/48
(0.00-1.00)×Rated current of the inverter [A]
0.001-65.535 [Ω]
0.01-655.35 [mH]
0.01-655.35 [mH]
0.0001-6.5535 [V/(rad/s)]
0.001-9999.000 [kgm
]
2
0.001-65.535 [Ω]
0.01-655.35 [mH]
0.01-655.35 [mH]
1-1000 [%]
20.00-100.00 [%]
0.01-60.00 [s]
0-120 [%]
0.0-25.5 [%]
0.00-100.00 [%]
Normal
Initial Magnet Position
Estimation
Ver.275
Run
Mode
Defaults
Edit
A
B
Initial data
00
kW dependent
kW dependent
kW dependent
kW dependent
kW dependent
kW dependent
kW dependent V/(rad/s)
kW dependent
kW dependent
kW dependent
kW dependent
100
70.00[%]
1.00[s]
100[%]
8.0 [%]
10.00 [%]
0
Units
kW
Poles
A
Ω
mH
mH
kgm
2
Ω
mH
mH
%
%
s
%
%
%