Ver.3− − − − 18
Func.
Func.
Func.
Func.
Code
Code
Code
Code
b b b b 9 9 9 9 1 1 1 1 0 0 0 0
b b b b 9 9 9 9 11
11
11 11
b b b b 9 9 9 9 1 1 1 1 2 2 2 2
b b b b 9 9 9 9 1 1 1 1 3 3 3 3
Electronic thermal subtract function association parameter
Name
Name
Name
Name
Electronic thermal
subtraction function selection
Thermal subtraction time
Thermal subtraction time
constant
Thermal accumulation gain
Description
Description
Description
Description
...OFF
00
00
00
00
...Linear subtraction: pre-fixed ratio
0 0 0 0 1 1 1 1
...Linear subtraction: ratio set in b911
0 0 0 0 2 2 2 2
...Subtraction with first-order lag filter:
0 0 0 0 3 3 3 3
ratio set in b912
Out of warranty when setting less than initial
value (600[s])
[this function is valid when electronic thermal
protection selection (b910)=02]
0.10 to 100000.00[s] (upper four digits are
shown)
Out of warranty when setting less than initial
value (120[s])
[this function is valid when electronic thermal
protection selection (b910)=03
0.10 to 100000.00[s] (upper four digits are
shown)
Out of warranty when setting less than initial
value (100[%])
1.0 to 200.0 [%]
】