Warnings for Configuring Drive Parameters
WARNING: When parameter b012, level of electronic thermal setting, is set to
WARNING
WARNING
WARNING
motor FLA rating (Full Load Ampere nameplate rating), the inverter provides solid
state motor overload protection at 115% of motor FLA or equivalent. If parameter
B012 exceeds the motor FLA rating, the motor may overheat and damaged.
Parameter B012, level of electronic thermal setting, is a variable parameter.
Cautions for Configuring Drive Parameters
CAUTION: Be careful to avoid specifying a braking time that is long enough to
CAUTION
CAUTION
CAUTION
cause motor overheating. If you use DC braking, we recommend using a motor
with a built-in thermistor, and wiring it to the inverter's thermistor input (see
"Thermistor Thermal Protection" on page 4-24). Also refer to the motor
manufacturer's specifications for duty-cycle recommendations during DC braking.
HIGH VOLTAGE
HIGH VOLTAGE: When set RDY function ON, there will be a voltage appear at
HIGH VOLTAGE
HIGH VOLTAGE
motor output terminals U, V and W even if the motor is in stop mode. So never
touch the inverter power terminal even the motor is not running.
CAUTION:
CAUTION: Do not change Debug mode for safety reasons. Otherwise unexpected
CAUTION:
CAUTION:
performances may occur.
Warnings for Operations and Monitoring
WARNING
WARNING: Be sure to turn ON the input power supply only after closing the front
WARNING
WARNING
case. While the inverter is energized, be sure not to open the front case. Otherwise,
there is the danger of electric shock.
WARNING: Be sure not to operate electrical equipment with wet hands.
WARNING
WARNING
WARNING
Otherwise, there is the danger of electric shock.
WARNING
WARNING: While the inverter is energized, be sure not to touch the inverter
WARNING
WARNING
terminals even when the motor is stopped. Otherwise, there is the danger of
electric shock.
WARNING
WARNING: If the retry mode is selected, the motor may suddenly restart after a
WARNING
WARNING
trip stop. Be sure to stop the inverter before approaching the machine (be sure to
design the machine so that safety for personnel is secure even if it restarts.)
Otherwise, it may cause injury to personnel.
WARNING: If the power supply is cut OFF for a short period of time, the inverter
WARNING
WARNING
WARNING
may restart operating after the power supply recovers if the Run command is
active. If a restart may pose danger to personnel, so be sure to use a lock-out
circuit so that it will not restart after power recovery. Otherwise, it may cause
injury to personnel.
WARNING: The Stop Key is effective only when the stop function is enabled. Be
WARNING
WARNING
WARNING
sure to enable the Stop Key separately from the emergency stop. Otherwise, it may
cause injury to personnel.
WARNING
WARNING: During a trip event, if the alarm reset is applied and the Run
WARNING
WARNING
command is present, the inverter will automatically restart. Be sure to apply the
alarm reset only after verifying the Run command is OFF. Otherwise, it may cause
injury to personnel.
...