Input Range Settings – The parameters in the following table adjust the input
characteristics of the VR (POT meter on external operator) input. When using the
inputs to command the inverter output frequency, these parameters adjust the starting
and ending ranges for the current, as well as the output frequency range. Related
characteristic diagrams are located in "
Analog sampling setting is the value specified in .
Func.
Name
Code
[VR] input active range start
frequency
[VR] input active range end
frequency
[VR] input active range
start %
[VR] input active range end %
[VR] input start frequency
select
Refer to parameter to for analog voltage input.
Analog Input Settings
"A" Function
Description
The output frequency
corresponding to the analog
input range starting point,
range is 0.0 to 400.0 Hz
The output frequency
corresponding to the current
input range ending point,
range is 0.0 to 400.0 Hz
The starting point (offset) for
the current input range,
range is 0. to 100.%
The ending point (offset) for
the current input range,
range is 0. to 100.%
Two options; select codes:
Use offset ( value)
Use 0Hz
" in this chapter.
Run
Defaults
Mode
Initial data
Units
Edit
0.00
Hz
0.00
Hz
0.
%
100.
%
01
343