■Operating procedure
Step 1:Set to motor
capacity, motor pole and
motor current according
to the motor.
Motor
capacity
Motor pole
Motor
current
After completing
auto-tuning, display of
auto-tuning result.
Normal
end
Abnormal
end
Step 5:After completing
auto-tuning, to clear the
result display, press the
STOP/RESET key.
STOP
Step 6:Measured motor
constants is reflected in
driving data.
SE T
Step 2:Set to base frequency,
maximum frequency and
motor voltage according to
the motor.
Base
frequency
Maximum
frequency
Motor voltage
Automatic driving begins.
When the operation command is input, the inverter
performs an automatic operation in the following steps:
(1) Initial Magnet Position Estimation
(Motor don't revolution)
↓
(2) First DC excitation (Motor don't revolution)
↓
(3) First AC excitation (Motor don't revolution)
↓
(4) Second AC excitation (Motor don't revolution)
↓
(5) Display of auto-tuning result
Step 3:02 is set to
Auto-tuning Setting
(H001).
SE T
Step 4:The operation
command is input
according to setting the
run command source
(A002).
RUN