Hitachi WJ200-001S Instruction Manual page 376

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Register
Function name
No.
Output [11]
1415h
function
Output [12]
1416h
function
1421h to
(Reserved)
1423h
Alarm relay
141Ah
function
[EO] terminal
141Bh
selection
[AM] terminal
141Ch
selection
141Dh
(reserved)
Digital current
141Eh
monitor reference
value
Output [11] active
141Fh
state
Output [12] active
1420h
state
1421h to
(Reserved)
1423h
Alarm relay active
1424h
state
1425h
(Reserved)
Output mode of
1426h
low current
detection
Low current
1427h
detection level
Overload signal
1428h
output mode
Overload warning
1429h
level
Function code
R/W
0 (RUN: running), 1 (FA1: constant-speed reached), 2
(FA2: set frequency overreached), 3 (OL: overload
notice advance signal (1)), 4 (OD: output deviation for
PID control), 5 (AL: alarm signal), 6 (FA3: set
frequency reached), 7 (OTQ: over-torque), 9 (UV:
C021
R/W
undervoltage), 10 (TRQ: torque limited), 11 (RNT:
operation time over), 12 (ONT: plug-in time over), 13
(THM: thermal alarm signal), 19 (BRK: brake release),
20 (BER: braking error), 21 (ZS: 0 Hz detection
signal), 22 (DSE: speed deviation maximum), 23
(POK: positioning completed), 24 (FA4: set frequency
overreached 2), 25 (FA5: set frequency reached 2), 26
(OL2: overload notice advance signal (2)), 31 (FBV:
PID feedback comparison), 32 (NDc: communication
line disconnection), 33 (LOG1: logical operation result
1), 34 (LOG2: logical operation result 2), 35 (LOG3:
C022
R/W
logical operation result 3), 39 (WAC: capacitor life
warning), 40 (WAF: cooling-fan), 41 (FR: starting
contact signal), 42 (OHF: heat sink overheat warning),
43 (LOC: low-current indication signal), 44 (M01:
general-purpose output 1), 45 (M02: general-purpose
output 2), 46 (M03: general-purpose output 3), 50
(IRDY: inverter ready), 51 (FWR: forward rotation), 52
-
-
(RVR: reverse rotation), 53 (MJA: major failur)
54 (WCO: window comparator O), 55 (WCO: window
comparator OI),
C026
R/W
58(FREF),59(REF),60(SETM),62(EDM),63(OPO:Opti
on)
0 (output frequency), 1 (output current), 2 (output
torque), 3 (digital output frequency), 4 (output
voltage), 5 (input power), 6 (electronic thermal
C027
R/W
overload), 7 (LAD frequency), 8 (digital current
monitoring), 10 (heat sink temperature), 12
(general-purpose output YA0),15 ,16(option)
0 (output frequency), 1 (output current), 2 (output
torque), 4 (output voltage), 5 (input power), 6
C028
R/W
(electronic thermal overload), 7 (LAD frequency), 10
(heat sink temperature), 11 (output torque [signed
value]), 13 (general-purpose output YA1),16(option)
-
-
-
C030
R/W
200 to 2000
C031
R/W
0 (NO), 1 (NC)
C032
R/W
0 (NO), 1 (NC)
-
-
-
C036
R/W
0 (NO), 1 (NC)
-
-
-
0 (output during acceleration/deceleration and
C038
R/W
constant-speed operation), 1 (output only during
constant-speed operation)
C039
R/W
0 to 2000
00 (output during acceleration/deceleration and
C040
R/W
constant-speed operation), 01 (output only during
constant-speed operation)
C041
R/W
0 to 2000
Monitoring and setting items
B41
Data
resolution
-
-
-
-
-
-
-
0.1 [%]
-
-
-
-
-
-
0.1 [%]
-
0.1 [%]