Hitachi WJ200-001S Instruction Manual page 490

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Func.
Name
Code
BRD activation level

(As DC Voltage)
BRD register


Free V/F setting, freq.1
Free V/F setting, voltage.1


Free V/F setting, freq.2

Free V/F setting, voltage.2
Free V/F setting, freq.3


Free V/F setting, voltage.3
Free V/F setting, freq.4

Free V/F setting, voltage.4


Free V/F setting, freq.5
Free V/F setting, voltage.5

Free V/F setting, freq.6


Free V/F setting, voltage.6
Free V/F setting, freq.7

Free V/F setting, voltage.7

Brake control enable

Brake Wait Time for Release

Brake Wait Time for

Acceleration
Brake Wait Time for

Stopping
Brake Wait Time for

Confirmation
Brake release freq.

Brake release current

Braking freq. setting

Deceleration overvoltage

suppression enable
Decel. overvolt. suppress

level
"b" Function
Description
If DC Voltage > b096,
the register consume. regeneration
power.
Range is:
330 to 380V (200V class)
660 to 760V (400V class)
Set the value of the register connected to
the inverter.By this setting, b090's upper
limit as the inverter hardware is
calcurated automatically.So, you can
focus the usage ratio as the connected
register.
Range is minimum connectable register
Rbmin to 600.0[Ω]
Set range, 0 ~ value of 
Set range, 0 ~ 800V
Set range, value of  ~
Set range, 0 ~ 800V
Set range, value of  ~
Set range, 0 ~ 800V
Set range, value of  ~
Set range, 0 ~ 800V
Set range, value of  ~
Set range, 0 ~ 800V
Set range, value of  ~
Set range, 0 ~ 800V
Set range,  ~ 400
Set range, 0 ~ 800V
Two option codes:
Disable
Enable
Set range: 0.00 to 5.00 seconds.
Set range: 0.00 to 5.00 seconds.
Set range: 0.00 to 5.00 s seconds.
Set range: 0.00 to 5.00 seconds.
Set range: 0 to 400Hz
Set range: 0~200% of inverter rated
current
Set range: 0 to 400Hz
Disabled
Enabled
Enabled with accel.
DC bus voltage of suppression. Range is:
200V class330 to 395
400V class660 to 790
Ver.261
Run
Mode
Defaults
Edit
A
B
Initial data
Units
360/
720
Min.
Resistance
 
0.
 
0.0
 
0.
 
0.0
 
0.
 
0.0
 
0.
 
0.0
 
0.
 
0.0
 
0.
 
0.0
 
0.
 
0.0
00
0.00
0.00
0.00
0.00
0.00
(rated
current)
0.00
00
380
/760
V
Ω
Hz
V
Hz
V
Hz
V
Hz
V
Hz
V
Hz
V
Hz
V
-
s
s
s
s
Hz
A
Hz
V