(iv) List of registers
Register
Function name
No.
1103h
Acceleration time (1)
1104h
1105h
Deceleration time (1)
1106h
1107h
Keypad Run key routing
1108h to
Unused
1200h
(v) List of registers (function modes)
Parameter group A
Register
Function name
No.
1201h
Frequency source
1202h
Run command source (*)
1203h
Base frequency
1204h
Maximum frequency
1205h
[AT] selection
1206h to
(Reserved)
120Ah
120Bh
[O] input active range start
120Ch
frequency
120Dh
[O] input active range end
frequency
120Eh
[O] input active range start
120Fh
voltage
[O] input active range end
1210h
voltage
[O] input start frequency
1211h
select
1212h
Analog input filter.
1213h
EzSQ selection
1214h
(Reserved)
Multi speed operation
1215h
selection
1216h
Multi-speed freq. 0
1217h
1218h
Multi-speed freq. 1
1219h
121Ah
Multi-speed freq. 2
121Bh
121Ch
Multi-speed freq. 3
121Dh
121Eh
Multi-speed freq. 4
121Fh
1220h
Multi-speed freq. 5
1221h
1222h
Multi-speed freq. 6
1223h
1224h
Multi-speed freq. 7
1225h
After changing the setting, keep the time 40ms or longer before actually give run command
Function code
R/W
F002 (high)
R/W
1 to 360000
F002 (low)
F003 (high)
R/W
1 to 360000
F003 (low)
F004
R/W
0 (forward rotation), 1 (reverse rotation)
-
-
Inaccessible
Function code
R/W
0 (keypad potentiometer), 1 (control circuit terminal
block), 2 (digital operator), 3 (Modbus), 4 (option ), 6
A001
R/W
(pulse train input), 7 (easy sequence), 10 (operation
function result)
1 (control circuit terminal block), 2 (digital operator),
A002
R/W
3 (Modbus), 4 (option)
A003
R/W
300 to "maximum frequency"
A004
R/W
300 to 4000(10000)
0 (switching between O and OI terminals),
2 (switching between O terminal and keypad
A005
R/W
potentiometer),
3 (switching between OI terminal and keypad
potentiometer)
-
-
-
A011 (high)
R/W
0 to 40000(100000)
A011 (low)
A012 (high)
R/W
0 to 40000(100000)
A012 (low)
A013
R/W
0 to "[O]-[L] input active range end voltage"
A014
R/W
"[O]-[L] input active range start voltage" to 100
A015
R/W
0 (external start frequency), 1 (0 Hz)
A016
R/W
1 to 30 or 31 (500 ms filter ±0.1 Hz with hysteresis)
A017
R/W
0 (disabling), 1 (PRG terminal) , 2 (Always)
-
-
-
A019
R/W
0 (binary), 1 (bit)
A020 (high)
R/W
0 or "start frequency" to "maximum frequency"
A020 (low)
R/W
A021 (high)
R/W
0 or "start frequency" to "maximum frequency"
A021 (low)
R/W
A022 (high)
R/W
0 or "start frequency" to "maximum frequency"
A022 (low)
R/W
A023 (high)
R/W
0 or "start frequency" to "maximum frequency"
A023 (low)
R/W
A024 (high)
R/W
0 or "start frequency" to "maximum frequency"
A024 (low)
R/W
A025 (high)
R/W
0 or "start frequency" to "maximum frequency"
A025 (low)
R/W
A026 (high)
R/W
0 or "start frequency" to "maximum frequency"
A026 (low)
R/W
A027 (high)
R/W
0 or "start frequency" to "maximum frequency"
A027 (low)
R/W
Monitoring and setting items
Monitoring and setting items
Ver.225
Data resolution
0.01 [s]
0.01 [s]
-
-
Data resolution
-
-
0.1 [Hz]
0.1 [Hz]
-
-
0.01 [Hz]
0.01 [Hz]
1 [%]
1 [%]
-
1
-
-
-
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]