Ver.258
Func.
Code
Current level of active freq.
matching
Deceleration rate of active
freq. matching
Start freq. of active freq.
matching
Software lock mode selection
Motor cable length
parameter
Run/power ON warning time
Rotation direction restriction
Reduced voltage start
selection
Function code display
restriction
Initial display selection
Automatic user parameter
registration
Torque limit selection
Torque limit 1 (fwd/power)
Torque limit 2 (fwd/power)
"b" Function
Name
Sets the current level of active freq.
matching restart, range is 0.1*inverter
rated current to 2.0*inverter rated
current, resolution 0.1 seconds.
Sets the deceleration rate when active
freq. matching restart, range is 0.1 to
3000.0, resolution 0.1 seconds.
Three option codes:
freq at previous shutoff
start from max. Hz
start from set frequency
Prevents parameter changes, in five
options, option codes:
all parameters except are locked
when [SFT] terminal is ON
all parameters except and
output frequency are locked
when [SFT] terminal is ON
all parameters except are
locked
all parameters except and
output frequency are locked
High level access including
See appendix C for the accessible
parameters in this mode.
Set range is 5 to 20.
Range is,
.:Warning disabled
. to .:
10~99,990 hrs (unit: 10)
to :
100,000~655,350 hrs (unit: 100)
Three option codes:
No restriction
Reverse rotation is restricted
Forward rotation is restricted
Set range, (disabling the function),
(approx. 6ms) to (approx. 1.5s)
Six option codes:
Full display
Function-specific display
User setting (and )
Data comparison display
Basic display
Monitor display only
Func. code that SET key pressed
last displayed.(*)
~~ displayed
displayed
B display of LCD operator
Two option codes:
Disable
Enable
Three option codes:
Quadrant-specific setting mode
Terminal-switching mode
Analog voltage input mode(O)
Torque limit level in forward powering
quadrant, range is 0 to 200%/no(disabled)
Torque limit level in forward powering
quadrant, range is 0 to 200%/no(disabled)
Description
Run
Mode
Defaults
Edit
A
B
Initial data
Units
Rated
current
0.5
00
01
10.
0.
00
2
00
001
00
00
200
200
A
s
Hrs.
%
%