Hitachi WJ200-001S Instruction Manual page 448

Wj200 series single/three-phase inputs 200v/400v class
Hide thumbs Also See for WJ200-001S:
Table of Contents

Advertisement

Coil
No.
002Dh
OL2 (overload notice advance (2))
002Eh
Odc: Analog O disconnection detection
OIDc: Analog OI disconnection
002Fh
detection
0030h
(Reserved)
0031h
(Reserved)
0032h
FBV (PID feedback comparison)
NDc (communication train
0033h
disconnection)
0034h
LOG1 (logical operation result 1)
0035h
LOG2 (logical operation result 2)
0036h
LOG3 (logical operation result 3)
0037h
(Reserved)
0038h
(Reserved)
0039h
(Reserved)
003Ah
WAC (capacitor life warning)
003Bh
WAF (cooling-fan speed drop)
003Ch
FR (starting contact signal)
003Dh
OHF (heat sink overheat warning)
003Eh
LOC (low-current indication signal)
003Fh
M01 (general output 1)
0040h
M02 (general output 2)
0041h
M03 (general output 3)
0042h
(Reserved)
0043h
(Reserved)
0044h
(Reserved)
0045h
IRDY (inverter ready)
0046h
FWR (forward rotation)
0047h
RVR (reverse rotation)
0048h
MJA (major failure)
0049h
Data writing in progress
004Ah
CRC error
004Bh
Overrun
004Ch
Framing error
004Dh
Parity error
004Eh
Sum check error
004Fh
(Reserved)
0050h
WCO (window comparator O)
0051h
WCOI (window comparator OI)
0052h
(Reserved)
0053h
OPDc (option disconnection)
0054h
FREF (FQ command source)
0055h
REF (RUN command source)
0056h
SETM (2nd motor selected)
0057h
(Reserved)
0058h
EDM (Gate suppress monitor)
0059h-
unused
*1 Normally, this coil is turned on when the corresponding intelligent input terminal on the control circuit terminal
block is turned on or the coil itself is set to on. In this regard, the operation of the intelligent input terminal has
priority over the operation of the coil. If disconnection of the communication train has disabled the master system
from turning off the coil, turn the corresponding intelligent input terminal on the control circuit block on and off.
This operation turns off the coil.
*2 Communication error data is retained until an error reset command is input. (The data can be reset during the
inverter operation.)
Item
R/W
R
-
-
-
-
R
R
R
R
R
-
-
-
R
R
R
R
R
R
R
R
-
-
-
R
R
R
R
R
R
R
R
R
R
-
R
R
-
R
R
R
R
-
R
R
Setting
1: ON, 0: OFF
1: ON, 0: OFF
1: ON, 0: OFF
-
-
1: ON, 0: OFF
1: ON, 0: OFF
1: ON, 0: OFF
1: ON, 0: OFF
1: ON, 0: OFF
-
-
-
1: ON, 0: OFF
1: ON, 0: OFF
1: ON, 0: OFF
1: ON, 0: OFF
1: ON, 0: OFF
1: ON, 0: OFF
1: ON, 0: OFF
1: ON, 0: OFF
-
-
-
1: ON, 0: OFF
1: ON, 0: OFF
1: ON, 0: OFF
1: ON, 0: OFF
1: Writing in progress, 0: Normal status
1: Error detected, 0: No error (*2)
1: Error detected, 0: No error (*2)
1: Error detected, 0: No error (*2)
1: Error detected, 0: No error (*2)
1: Error detected, 0: No error (*2)
-
1: ON, 0: OFF
1: ON, 0: OFF
-
1: ON, 0: OFF
1: Operator, 0: Others
1: Operator, 0: Others
1: 2nd motor selected, 0: 1st motor selected
-
1: ON, 0: OFF
inaccessible
Ver.219