Ver.262
Func.
Code
Decel. overvolt. suppress

const.
Decel. overvolt. suppress

proportional gain
Decel. overvolt. suppress

integral time
GS input mode

Display ex.operator

connected
1st parameter of Dual

Monitor
2nd parameter of Dual

Monitor
Frequency set in monitoring

Automatic return to the

initial display
Ex. operator com. loss action

Data Read/Write select

Inverter mode selection

Initialization trigger

(*)

Password Settings A
Password authentication A

Password Settings B

Password authentication B

"b" Function
Name
Accel. rate when b130=02.
Set range: 0.10 ~ 30.00 seconds.
Proportional gain when b130=01. Range
is: 0.00 to 5.00
Integration time when b130=01. Range
is: 0.00 to 150.0 seconds.
Two option codes:
No trip (Hardware shutoff only)
Trip
When an external operator is connected
via RS-422 port, the built-in display is
locked and shows only one "d" parameter
configured in:
 ~ 
Set any two "d" parameters in b160 and
b161, then they can be monitored in d050.
The two parameters are switched by
up/down keys.
Set range:  ~ 
Two option codes:
Freq. set disabled
Freq. set enabled
10 min. after the last key operation,
display returns to the initial parameter
set by . Two option codes:
Disable
Enable
Five option codes:
Trip
Trip after deceleration to a stop
Ignore
Coasting (FRS)
Decelerates to a stop
 Read/Write OK
 Protected
Three option codes:
No function
Std. IM (Induction Motor)
PM(Permanent Magnet Motor)
This is to perform initialization by
parameter input with ,  and
. Two option codes:
Initialization disable
Perform initialization
0000(Invalid Password)
0001-FFFF(Password)
0000-FFFF
0000(Invalid Password)
0001-FFFF(Password)
0000-FFFF
Description
Run
Mode
Defaults
Edit
A
B
Initial data
Units
1.00
0.20
1.0
00
001
001
002
00
00
02
00
00
 
00
 
0000
 
0000
 
0000
 
0000
 
s
s